A numerical solution to estimate hydro-geologic parameters of a fractured geothermal porous medium based on fluorescein thermal decay correction
View/ Open
Date
2014-07Author
Wang’ombe, Benson
Okiambe, Enock
Omenda, Peter
Rathore, I.V.S.
Ambusso, Willis
Metadata
Show full item recordAbstract
A numerical solution to model the flow of fluorescein tracer in a fractured, high temperature
geothermal system is presented. This study was carried out in Olkaria, Kenya. Results show that
correcting for fluorescein decay at elevated temperatures can be used to yield reservoir hydro-geologic
parameters and improve the methods of evaluating effects of injected fluids on reservoir temperature.
The hydro-geologic parameters for this study are better than those obtained by other methods. This
outcome was obtained by solving the material, tracer and energy balance equations that were fully
discretized using integral finite difference and solved by Gauss–Seidel recursive methods. A computer
code in C++ had to be written to perform the simulations. Porosity and permeability were seen to range
between 11 and 16% and 1.8–2.6 Darcy respectively. Reservoir pore volume along well OW-12 and
OW-19 flow path was approximately 17–26 million litres whilst recharge rate was 7 kg/s. This proves
that computational methods such as those considered here can be used for industrial application.
Furthermore, fluorescein being cheap and benign to environment can be made applicable in high
temperature geothermal systems.